What type of cut is used to create a fire break that stops the spread of fire in common attic structures or large structures?


A) Trench cut
B) Vertical cut
C) Exhaust cut
D) Offensive cut

Correct Answer

verifed

verified

Ventilation that causes heat, smoke, and fire to be discharged through wall openings below the highest point of the building creates danger because:


A) multiple ventilation points will be created from the openings.
B) oxygen levels will be increased for the upper levels of the fire.
C) fire streams will be unable to reach the higher levels of the fire.
D) rising gases will ignite portions of the building above exhaust point.

Correct Answer

verifed

verified

Which of the following factors have a bearing on deciding where to ventilate?


A) Number of bystanders
B) Cost of ventilation operations
C) Availability of rehabilitation facilities
D) Indications of potential structural collapse

Correct Answer

verifed

verified

D

Opening doors or windows is an example of:


A) natural ventilation.
B) vertical ventilation.
C) hydraulic ventilation.
D) mechanical ventilation.

Correct Answer

verifed

verified

When the main body of the fire is too great to extinguish, and only after the offensive vertical ventilation opening has been made, a trench cut must be created ahead of the advancing fire by at least:


A) 10 feet.
B) 20 feet.
C) 30 feet.
D) 40 feet.

Correct Answer

verifed

verified

C

The automatic closure of doors, petitions, windows, and HVAC systems are methods of:


A) compartmentalizing a structure.
B) confining fire operations personnel.
C) evacuating occupants of the structure.
D) verifying combustibles adjacent to the fire floor.

Correct Answer

verifed

verified

When performing tactical ventilation, the highest incident priority is:


A) life safety.
B) risk mitigation.
C) extinguishment.
D) incident stabilization.

Correct Answer

verifed

verified

Which of the following personnel determines if ventilation is necessary?


A) Battalion chief
B) Senior firefighter
C) Incident Commander
D) Any firefighter can make the determination

Correct Answer

verifed

verified

In a structure fire, what part of the flow path is an open doorway?


A) Inlet vent
B) Outlet vent
C) Lower vent
D) Upper vent

Correct Answer

verifed

verified

Positive-pressure ventilation (PPV) exhaust openings vary with the size of the entry opening and the:


A) capacity of hose lines.
B) capacity of the blower used.
C) number of personnel on site.
D) number of compartments in the structure.

Correct Answer

verifed

verified

Offensive vertical ventilation is intended to aid in reaching and:


A) extinguishing the fire.
B) stopping the spread of fire.
C) containing the fire to one area of the structure.
D) determining the effect on exposures to the fire.

Correct Answer

verifed

verified

An inspection hole should be cut before cutting any type of ventilation hole in the roof in an attic or cockloft fire to:


A) ensure roof is safe.
B) ensure minimal secondary damage.
C) determine the fire location and direction of travel.
D) determine at least two means of egress from the roof.

Correct Answer

verifed

verified

Which of the following should be indicated by a smoke control system control panel?


A) What initiated the fire
B) Who activated the alarm
C) Where the alarm originated
D) When the system will turn off

Correct Answer

verifed

verified

When ventilating a multistory building, it is best to apply positive-pressure ventilation (PPV) :


A) on the floor with the least smoke.
B) on the floor with the most smoke.
C) at the highest point of the structure.
D) at the lowest point of the structure.

Correct Answer

verifed

verified

D

Which fire behavior indicator provides visual indicators such as the size and location of the fire?


A) Heat
B) Smoke
C) Flame
D) Air flow

Correct Answer

verifed

verified

Which of the following factors is a primary reason that firefighters should not create tactical ventilation openings in an uncoordinated manner?


A) Can spread fire to uninvolved areas
B) May damage roof of structure by creating openings
C) Can cause fire streams to have negative affect on fire
D) Creating openings does unnecessary damage to the structure

Correct Answer

verifed

verified

Which type of ventilation requires no additional personnel or equipment to set up and maintain?


A) Vertical
B) Hydraulic
C) Natural horizontal
D) Mechanical horizontal

Correct Answer

verifed

verified

Which characteristic of modern construction produces large quantities of toxic, combustible gases during a fire?


A) Energy efficient designs
B) Treated wood components
C) Lightweight structural components
D) Use of plastics and other synthetic materials

Correct Answer

verifed

verified

Cutting a hole in the roof above the fire or opening existing roof access doors, scuttles, or skylights are all examples of:


A) inlet ventilation.
B) outlet ventilation.
C) vertical ventilation.
D) horizontal ventilation.

Correct Answer

verifed

verified

Incident stabilization means:


A) reducing interior temperatures.
B) increasing oxygen concentration.
C) controlling and extinguishing the fire in stages.
D) increasing the number of smoke-free paths of egress.

Correct Answer

verifed

verified