Filters
Question type

Study Flashcards

For a permanently installed swimming pool, any 15 or 20 amp, 125 through 250 volt rated receptacle located within __________ feet of a pool's inside wall must be GFCI protected.


A) 3
B) 10
C) 12
D) 20

Correct Answer

verifed

verified

Describe a multiwire branch circuit.

Correct Answer

verifed

verified

a branch circuit that consists of two or more ungrounded conductors that have a voltage between them and a grounded conductor that has an equal voltage between it and each ungrounded conductor

The most important installation practice for a permanently installed swimming pool is the proper grounding and bonding together of all ____________________ parts in and around the pool.

Correct Answer

verifed

verified

A permanently installed swimming pool must have at least one 125-volt, 15- or 20-amp receptacle located a minimum of __________ feet from the inside wall of the pool.


A) 3
B) 5
C) 6
D) 10

Correct Answer

verifed

verified

Lighting fixture assemblies for storage pools are permitted as long as the lamp operates at no more than __________ volts.


A) 15
B) 24
C) 120
D) 240

Correct Answer

verifed

verified

If a conductor or cable has a(n) ____________________ in their insulation designation, such as THWN, it means that it is suitable for installation in a wet location.

Correct Answer

verifed

verified

W

When bonding the various metal parts of a permanently installed swimming pool, all bonding wires must be solid copper and be ____ AWG or larger.


A) 10
B) 8
C) 6
D) 4

Correct Answer

verifed

verified

A light-sensing device used to control lighting fixtures in response to detected light levels is called a _________.


A) transfer switch
B) no-niche luminaire
C) dry-niche luminaire
D) photocell

Correct Answer

verifed

verified

The conductors that provide power to pool lighting fixtures must be GFCI protected if the voltage is above __________ volts.


A) 15
B) 24
C) 120
D) 240

Correct Answer

verifed

verified

The minimum burial depth for type UF cable can be found in Table __________ of the NEC.


A) 110.26
B) 220.12
C) 300.5
D) 310.15(B) (16)

Correct Answer

verifed

verified

A GFCI receptacle is an acceptable means to provide the required GFCI protection to a hydromassage bathtub.

Correct Answer

verifed

verified

Outdoor lighting can be mounted on trees.

Correct Answer

verifed

verified

If the feeder supplying power to a detached garage is installed with an equipment grounding conductor, the NEC does not require a separate grounding electrode system to be established.

Correct Answer

verifed

verified

According to the NEC, the minimum burial depth for a direct buried cable like Type UF is __________ inches.(General Rule)


A) 6
B) 12
C) 18
D) 24

Correct Answer

verifed

verified

If a lighting fixture is installed under a canopy or under an open porch, it is considered to be in a(n) ____________________ location.

Correct Answer

verifed

verified

PVC conduit is not permitted as the only means of support for a junction box used with underwater lighting when wiring permanently installed swimming pools.

Correct Answer

verifed

verified

Pool motors can be cord and plug connected but if they are, the cord can't be more than __________ feet long and must contain an equipment grounding conductor sized according to Table 250.122.


A) 1
B) 2
C) 3
D) 4

Correct Answer

verifed

verified

C

Overhead conductor spans are permitted to be supported by trees.

Correct Answer

verifed

verified

A(n) ____________________ switch eliminates the possibility of a generator voltage being applied to the secondary of the utility's supply transformer.

Correct Answer

verifed

verified

Assuming a 20 amp circuit breaker and GFCI protection, the minimum burial depth for a Type UF cable running to a 120 volt pole light at a residence is __________ inches.


A) 6
B) 12
C) 18
D) 24

Correct Answer

verifed

verified

Showing 1 - 20 of 45

Related Exams

Show Answer