If the densities seen on the test film appear lighter than those seen on the reference radiographs,the developer solution is (1) weak,(2) too concentrated,(3) cold,and/or (4) too warm.


A) 1 and 3
B) 1 and 4
C) 2 and 3
D) 2 and 4

Correct Answer

verifed

verified

Where would you place the wire mesh if you were conducting a film-screen test?


A) On top of the loaded cassette
B) On the side of the film closest to the tubehead within the loaded cassette
C) On the side of the film farthest from the tubehead within the loaded cassette
D) Over the end of the PID

Correct Answer

verifed

verified

A reference radiograph is used to evaluate


A) the viewbox.
B) darkroom lighting.
C) safelighting.
D) developer strength.

Correct Answer

verifed

verified

Your dental office should monitor retakes in a retake log in order to identify recurring problems and improve the quality of future images?


A) Both statement and reason are true.
B) Both statement and reason are false.
C) The statement is true;the reason is false.
D) The statement is false;the reason is true.

Correct Answer

verifed

verified

A

Which of the following statements is true of the evaluation of the film-screen contact test?


A) Areas of poor film-screen contact appear darker than good contact areas.
B) Areas of poor film-screen contact appear lighter than good contact areas.
C) If the wire mesh image on the film exhibits varying densities,good film-screen contact has taken place.
D) Both a and c

Correct Answer

verifed

verified

To conduct the film-screen contact test,the position-indicating device (PID) should have a ____-inch target-film distance.


A) 6
B) 12
C) 40
D) 72

Correct Answer

verifed

verified

C

Prior to using the developer each day,you compare the reference radiograph to a test film that you develop to check to see if the developer chemicals are depleted.What are you comparing when you look at the two films?


A) Milliamperage
B) kVp
C) Color
D) Density

Correct Answer

verifed

verified

A film-screen contact test is used to test the


A) output of the x-ray machine.
B) quality of intraoral films.
C) cassette holder for extraoral films.
D) freshness of extraoral film.

Correct Answer

verifed

verified

To conduct the coin test,the film and coin are exposed for


A) 10 seconds.
B) 3 or 4 minutes.
C) 15 minutes.
D) an entire workday.

Correct Answer

verifed

verified

The stepwedge technique for evaluating developer strength relies on exposing one exposed stepwedge film


A) each day.
B) each week.
C) every time 20 films have been processed.
D) every time 40 films have been processed.

Correct Answer

verifed

verified

The clearing test is used to monitor


A) developer strength.
B) fixer strength.
C) water bath temperature.
D) processing speed.

Correct Answer

verifed

verified

To perform the coin test,the film and coin are exposed to


A) the safelight.
B) the darkroom ceiling or white light.
C) the light with the darkroom door open.
D) no light at all.

Correct Answer

verifed

verified

You are performing a light leak test in the darkroom,which of the following would you do?


A) Use a flashlight to check for light leaks.
B) Turn the overhead lights off,and turn the safelight on.
C) Turn all darkroom lights off.
D) Light a match within the darkroom to see if any light is visible from the outside.

Correct Answer

verifed

verified

Where is the best place for you to view the radiograph that you used for the film screen contact test?


A) Dimly lit room at a distance of 1 foot from the viewbox.
B) Brightly lit room at a distance of 1 foot from the viewbox.
C) Dimly lit room at a distance of 6 feet from the viewbox.
D) Brightly lit room at a distance of 6 feet from the viewbox.

Correct Answer

verifed

verified

If the film clears in ____ minutes,the chemistry is of adequate strength.


A) 2
B) 6
C) 8
D) 14

Correct Answer

verifed

verified

If the image of the coin appears on the processed radiograph after the coin test


A) the safelight is safe to use with that type of film.
B) the safelight is not safe to use with that type of film.
C) conduct the test again with the darkroom door closed rather than open.
D) conduct the test again with the safelight off rather than on.

Correct Answer

verifed

verified

A calibration test for accurate kilovoltage and milliamperage readings would most likely be performed to ensure that the dental ____________ is functioning properly.


A) x-ray machine
B) film
C) film processing
D) darkroom

Correct Answer

verifed

verified

According to the test for dental x-ray film,if the processed film appears clear with a slight blue tint,the film


A) has expired.
B) is fresh and has been properly stored and protected.
C) has been improperly stored.
D) has been exposed to radiation.

Correct Answer

verifed

verified

B

To create a reference radiograph,which of the following must be fresh? 1) Film 2) Developer 3) Fixer


A) 1,2,3
B) 1,2
C) 2,3
D) 1 only

Correct Answer

verifed

verified

If the processor is functioning properly,the results of the automatic processor test films will be that


A) the unexposed film appears clear and dry,and the film exposed to light appears black and dry.
B) the unexposed film appears clear and wet,and the film exposed to light appears black and wet.
C) the unexposed film appears black and dry,and the film exposed to light appears clear and dry.
D) the unexposed film appears black and wet,and the film exposed to light appears clear and wet.

Correct Answer

verifed

verified