Match the following choices with the correct statement as each is related to automatic exposure control technology. -AP hip


A) phototiming
B) minimum response time
C) backup mAs
D) underexposed image
E) overexposed image
F) density controls
G) all three detectors
H) center detector only

Correct Answer

verifed

verified

When more than one ionization chamber is used, the signal is


A) averaged.
B) muted.
C) multiplied.
D) all of the above

Correct Answer

verifed

verified

Contemporary AEC systems work on the x-ray property


A) causing certain crystals to fluoresce.
B) causing ionization of gases.
C) of producing small amounts of heat as they pass through matter.
D) affecting photographic film.

Correct Answer

verifed

verified

A new high frequency radiographic system is being released to a customer for first clinical use.The applications person states that the AEC density controls are in 20% increments.If a normal AEC exposure of the hip is 24 mAs, a repeat exposure at +2 would yield a mAs value of


A) 26 mAs.
B) 29 mAs.
C) 34 mAs.
D) 48 mAs.

Correct Answer

verifed

verified

When using APR for a radiographic exposure,


A) AEC may be turned off manually.
B) a backup mAs is already set.
C) programmed AEC chamber selections may be reconfigured.
D) all of the above

Correct Answer

verifed

verified

U.S.public law requires that generators automatically terminate AEC exposures at ____ mAs above 50 kVp.


A) 100
B) 300
C) 600
D) 900

Correct Answer

verifed

verified

When an AEC is used for a PA chest, which ionization chambers are utilized?


A) the center cell
B) the left and right outer cells
C) all three cells
D) the right outer cell only

Correct Answer

verifed

verified

B

Early versions of AEC technology were referred to as


A) photometers.
B) phototimers.
C) photosensors.
D) voltage regulators.

Correct Answer

verifed

verified

Match the following choices with the correct statement as each is related to automatic exposure control technology. -typically 0.001 sec


A) phototiming
B) minimum response time
C) backup mAs
D) underexposed image
E) overexposed image
F) density controls
G) all three detectors
H) center detector only

Correct Answer

verifed

verified

If the primary beam is collimated from an activated chamber, the result is a


A) light radiograph.
B) dark radiograph.
C) short exposure time.
D) decrease in radiographic density.

Correct Answer

verifed

verified

When an AEC is used for a lateral chest, which ionization chambers are utilized?


A) the center cell
B) the left and right outer cells
C) all three cells
D) the left outer cell only

Correct Answer

verifed

verified

Match the following choices with the correct statement as each is related to automatic exposure control technology. -Older technologists may still refer to it.


A) phototiming
B) minimum response time
C) backup mAs
D) underexposed image
E) overexposed image
F) density controls
G) all three detectors
H) center detector only

Correct Answer

verifed

verified

When an AEC is used for an AP hip, which ionization chambers are utilized?


A) the center cell
B) the left and right outer cells
C) all three cells
D) the left outer cell only

Correct Answer

verifed

verified

A radiographer is performing an AP knee radiograph using AEC.The manual technique for this exam would be 12 mAs at 80 kVp.The backup mAs the radiographer should set would be


A) 6 mAs.
B) 12 mAs.
C) 18 mAs.
D) 24 mAs.

Correct Answer

verifed

verified

C

The backup time of most AECs is set at ____ of the anticipated manual exposure time.


A) 10%
B) 50%
C) 100%
D) 150%

Correct Answer

verifed

verified

When an AEC is used for an AP lumbar spine, which ionization chambers are utilized?


A) the center cell
B) the left and right outer cells
C) all three cells
D) the right outer cell only

Correct Answer

verifed

verified

The single function of an AEC is to eliminate the need to set


A) kVp.
B) mA.
C) time.
D) all of the above

Correct Answer

verifed

verified

Automatic exposure devices provide a diagnostic quality radiograph when the


A) anatomy of interest is positioned directly above the appropriate ionization chambers.
B) proper time is set.
C) correct focal spot is selected.
D) beam filtration is minimum.

Correct Answer

verifed

verified

Match the following choices with the correct statement as each is related to automatic exposure control technology. -AP abdomen radiograph


A) phototiming
B) minimum response time
C) backup mAs
D) underexposed image
E) overexposed image
F) density controls
G) all three detectors
H) center detector only

Correct Answer

verifed

verified

G

When using an AEC, the radiographer loses control of


A) distance.
B) mA.
C) kVp.
D) mAs.

Correct Answer

verifed

verified