Generally speaking,patient dose will be decreased with the:


A) variable kVp-fixed mAs technique chart design.
B) variable kVp-variable mAs technique chart design.
C) fixed kVp-variable mAs technique chart design.
D) fixed kVp-fixed mAs technique chart design.

Correct Answer

verifed

verified

AEC eliminates the need for the radiographer to select the actual _____ the examination will require.


A) kVp
B) SID
C) exposure time
D) focal spot size

Correct Answer

verifed

verified

In order to become familiar with manual technical factors (i.e.,setting mAs and kVp and not using AEC) ,it is very helpful to pay attention to the:


A) exposure time.
B) heat units.
C) density control.
D) mAs readout.

Correct Answer

verifed

verified

If the detector is directly exposed to the primary beam during a film-screen study,the area of interest will appear:


A) overexposed.
B) underexposed.
C) correctly exposed.
D) to have high contrast.

Correct Answer

verifed

verified

What describes the shortest exposure time required for the AEC device to operate?


A) Backup time
B) Minimum response time
C) Master density time
D) A and B
E) A and C

Correct Answer

verifed

verified

Which automatic exposure device works by using a gas-filled chamber?


A) Phototimer
B) Diode sensor
C) Ionization chamber
D) Bucky proliferator

Correct Answer

verifed

verified

Accurate patient measurement is most critical for the:


A) variable kVp-fixed mAs technique chart design.
B) variable kVp-variable mAs technique chart design.
C) fixed kVp-variable mAs technique chart design.
D) fixed kVp-fixed mAs technique chart design.

Correct Answer

verifed

verified

Which exposure variable is controlled by the automatic exposure control device?


A) kVp
B) Focal spot size
C) Seconds
D) mA

Correct Answer

verifed

verified

A patient measuring 26 cm requires 20 mAs at 75 kVp based on a fixed kVp-variable mAs technique chart.What technique should be used for the next patient,who measures 34 cm?


A) 40 mAs at 75 kVp
B) 80 mAs at 75 kVp
C) 20 mAs at 91 kVp
D) 40 mAs at 91 kVp

Correct Answer

verifed

verified

What is the purpose of a technique chart?


A) To decrease the patient exposure by always using the highest kVp required
B) To ensure consistent image quality
C) To reduce the repeat imaging due to technique error and, in turn, reduce the patient exposure
D) A and B
E) B and C

Correct Answer

verifed

verified

Using the concept of comparative anatomy,if a child's elbow measures the same as an adult wrist and all other procedural variables are the same (i.e.,SID,image receptor type,etc.) ,the child's elbow will require _____ in comparison to the adult wrist.


A) less mAs
B) more mAs
C) the same mAs
D) higher kVp

Correct Answer

verifed

verified

The mAs readout:


A) is of little value because it's not necessary to know mAs when using AEC.
B) reports the actual mAs used for an exposure.
C) reports the patient dose for the entire imaging study.
D) allows the radiographer to better set the mAs for an AEC examination.

Correct Answer

verifed

verified

If a part measures 14 cm and requires the use of 75 kVp,how much kVp would a part measuring 18 cm require when using a variable kVp-fixed mAs technique chart?


A) 67 kVp
B) 77 kVp
C) 83 kVp
D) 91 kVp

Correct Answer

verifed

verified

A technique chart should be established for:


A) each radiographer.
B) each radiographic tube.
C) each radiologist.
D) A and B.
E) A and C.

Correct Answer

verifed

verified

When using AEC,what should the radiographer adjust to manipulate the contrast of the image?


A) kVp
B) Detector selection
C) Exposure time
D) Focal spot size

Correct Answer

verifed

verified

Which of the following is not part of a standardized technique chart?


A) SID
B) OID
C) mA
D) kVp

Correct Answer

verifed

verified

Where does a radiographer find the established guidelines for selecting exposure factors for a radiographic examination?


A) Technique chart
B) Generator control panel
C) Examination requisition
D) A or B
E) B or C

Correct Answer

verifed

verified

If the backup time/mAs is automatically set by the x-ray unit,the exposure should end when a maximum of _________ has been reached.


A) 600 s
B) 600 kVp
C) 600 mA
D) 600 mAs

Correct Answer

verifed

verified

Departmental standards,such as the SID or whether an examination is done tabletop or Bucky,should be determined:


A) prior to the development of technique charts.
B) after the development of technique charts.
C) at the same time as the development of technique charts.
D) whenever the department can come to an agreement.

Correct Answer

verifed

verified

A good reason to use AEC density control is to increase the exposure to the IR to compensate for improper centering.

Correct Answer

verifed

verified